Availability: | |
---|---|
Quantity: | |
YS102
Rated currents up to 10A
With 2 fuses for better safety
Integrated 2-pole rocker switch
Optional medical versions (M type)
IEC Connector Integrative Filter with 1 or 2 Fuses and Switch
General purpose, compact, easy for installation and use
A Practical solution to help your facility pass EMI system approval in a short time
Available for portable electronic equipment and measuring instruments
Apply to consumer goods, single -phase power supplies, switch-mode power supplies
Medical equipment and medical typical applications, low leakage current
Rated Voltage | 125/250VAC |
Operation Frequency | 50/60Hz |
Rated Current | 1-10A |
Hi-pot Test | 1450VDC 2 sec ( Line to Line) 2250VDC 2 sec ( Line to Ground) |
Climate Category | 25/85/21 (-25°C to +85°C) |
Model | Rated current (A) | Leakage current ≤( mA) | Circuit Diagram | Dim Fig | Fuse Qty | Output connection |
YS-102-1A-01D | 1A | 0.5 | Fig 1 | C3 | 2 | Standard |
YS-102-3A-01D | 3A | 0.5 | Fig 1 | C3 | 2 | Standard |
YS-102-6A-01D | 6A | 0.5 | Fig 1 | C3 | 2 | Standard |
YS-102-10A-01D | 10A | 0.5 | Fig 1 | C3 | 2 | Standard |
YS-102-1A-01DM | 1A | 0.01 | Fig 2 | C3 | 2 | Standard |
YS-102-3A-01DM | 3A | 0.01 | Fig 2 | C3 | 2 | Standard |
YS-102-6A-01DM | 6A | 0.01 | Fig 2 | C3 | 2 | Standard |
YS-102-10A-01DM | 10A | 0.01 | Fig 2 | C3 | 2 | Standard |
Insertion Loss in dB measured in a 50Ω/50Ωsystem, as IEC/CISPR No. 17 )
A=Differential mode B=Common Mode
Rated currents up to 10A
With 2 fuses for better safety
Integrated 2-pole rocker switch
Optional medical versions (M type)
IEC Connector Integrative Filter with 1 or 2 Fuses and Switch
General purpose, compact, easy for installation and use
A Practical solution to help your facility pass EMI system approval in a short time
Available for portable electronic equipment and measuring instruments
Apply to consumer goods, single -phase power supplies, switch-mode power supplies
Medical equipment and medical typical applications, low leakage current
Rated Voltage | 125/250VAC |
Operation Frequency | 50/60Hz |
Rated Current | 1-10A |
Hi-pot Test | 1450VDC 2 sec ( Line to Line) 2250VDC 2 sec ( Line to Ground) |
Climate Category | 25/85/21 (-25°C to +85°C) |
Model | Rated current (A) | Leakage current ≤( mA) | Circuit Diagram | Dim Fig | Fuse Qty | Output connection |
YS-102-1A-01D | 1A | 0.5 | Fig 1 | C3 | 2 | Standard |
YS-102-3A-01D | 3A | 0.5 | Fig 1 | C3 | 2 | Standard |
YS-102-6A-01D | 6A | 0.5 | Fig 1 | C3 | 2 | Standard |
YS-102-10A-01D | 10A | 0.5 | Fig 1 | C3 | 2 | Standard |
YS-102-1A-01DM | 1A | 0.01 | Fig 2 | C3 | 2 | Standard |
YS-102-3A-01DM | 3A | 0.01 | Fig 2 | C3 | 2 | Standard |
YS-102-6A-01DM | 6A | 0.01 | Fig 2 | C3 | 2 | Standard |
YS-102-10A-01DM | 10A | 0.01 | Fig 2 | C3 | 2 | Standard |
Insertion Loss in dB measured in a 50Ω/50Ωsystem, as IEC/CISPR No. 17 )
A=Differential mode B=Common Mode
The aluminum shell dynamic braking resistor is used in various applications to ensure the safe and controlled deceleration of electric motors. Here are some of its primary uses:• Heat Dissipation: The aluminum shell acts as a heat sink, dissipating the heat generated by the resistor during the brak
Calculating the dynamic braking resistor for a Variable Frequency Drive (VFD) involves determining the required resistance value and power rating. Here’s a step-by-step guide:### 1. Determine the System Parameters:- **Motor Power (P)**: in kW or HP.- **DC Bus Voltage (Vdc)**: typically provided by t
Aluminium-housed resistors offer several advantages in high-power industry applications, making them a preferred choice for many engineers and designers. Here are some of the key benefits:• Superior Heat Dissipation: The aluminium housing acts as a heat sink, rapidly dissipating heat during high-po
The electronic products industry market is changing rapidly, requiring basic components to keep up with the pace of product renewal. Especially in the past six months, to cope with the meager and efficient design of downstream general electronic products, some Inductors and transformer using new mat
The principle of the transformer is electromagnetic induction, which is mainly used to change the magnitude of the AC voltage. Transformers are used in the modern electrical industry. Transformers can be divided into many types and are used in many industries. Switching power supply transformers als
The principle of the transformer is electromagnetic induction, which is mainly used to change the magnitude of the AC voltage. Transformers are used in the modern electrical industry. Transformers can be divided into many types and are used in many industries. Switching power supply transformers als