Availability: | |
---|---|
Quantity: | |
RM
RM type is known for low magnetic leakage, low loss, wide operating frequency, and strong interference immunity. It has a shape which is suitable for high density power design and enable engineer to downsize the power supply
RM type power transformers are suitable for DC-DC converter, Switching AC-DC adapter, and compact size and high density of switching power supply.
Our engineer team can offer support with our customers for design support, and custom design is also welcome.
Reference type of RM transformerRM4RM5RM6RM8RM10RM12RM14
Type | Type Structure Type | Dimension (mm) | PIN 1ROW (mm) | PIN ROW 2 (mm) | Row Pitch (mm) | OD (PIN ) (mm) | ||||
A | B | C | Pin | Pin pitch | Pin | Pin pitch | ||||
RM5-1 | Vertical | 17.5 | 18.0 | 12.5 | 3 | 2.5 | 3 | 7.0/14.3 | 14.0 | Φ0.5 |
RM6-1 | Vertical | 19.0 | 24.5 | 14.5 | 4 | 4.0 | 4 | 7.0/14.3 | 15.0 | Φ0.5 |
RM6-2 | Vertical | 21.0 | 21.5 | 14.0 | 6 | 3.0 | 6 | 7.0/14.3 | 18.1 | Φ0.7 |
RM6-3 | Vertical | 21.0 | 21.0 | 13.5 | 3 | 3.6 | 3 | 7.0/14.3 | 18.2 | Φ0.5 |
RM6-4 | Vertical | 21.5 | 18.0 | 13.5 | 2 | 3.6 | 2 | 7.0/14.3 | 14.4 | Φ0.6 |
RM8-1 | Vertical | 26.0 | 25.0 | 18.0 | 6 | 3.5/7.0 | 6 | 7.0/14.3 | 18.0/14.3 | Φ0.6 |
RM8-2 | Vertical | 27.0 | 31.0 | 18.5 | 6 | 3.8 | 6 | 7.0/14.3 | 20.3 | Φ0.6 |
RM10-1 | Vertical | 31.0 | 29.0 | 20.0 | 6 | 3.6/7.2 | 6 | 7.0/14.3 | 18.2/21.5 | Φ0.6 |
RM10-2 | Vertical | 30.0 | 38.5 | 20.0 | 6 | 3.8 | 6 | 7.0/14.3 | 28.0 | Φ0.6 |
RM14-1 | Vertical | 44.0 | 43.0 | 30.0 | 6 | 7.0/14.3 | 6 | 7.0/14.3 | 25.2/32.3/25.5 | Φ0.8 |
RM14-2 | Vertical | 44.0 | 51.0 | 30.0 | 6 | 5.1 | 6 | 7.0/14.3 | 35.5 | Φ0.8 |
RM type is known for low magnetic leakage, low loss, wide operating frequency, and strong interference immunity. It has a shape which is suitable for high density power design and enable engineer to downsize the power supply
RM type power transformers are suitable for DC-DC converter, Switching AC-DC adapter, and compact size and high density of switching power supply.
Our engineer team can offer support with our customers for design support, and custom design is also welcome.
Reference type of RM transformerRM4RM5RM6RM8RM10RM12RM14
Type | Type Structure Type | Dimension (mm) | PIN 1ROW (mm) | PIN ROW 2 (mm) | Row Pitch (mm) | OD (PIN ) (mm) | ||||
A | B | C | Pin | Pin pitch | Pin | Pin pitch | ||||
RM5-1 | Vertical | 17.5 | 18.0 | 12.5 | 3 | 2.5 | 3 | 7.0/14.3 | 14.0 | Φ0.5 |
RM6-1 | Vertical | 19.0 | 24.5 | 14.5 | 4 | 4.0 | 4 | 7.0/14.3 | 15.0 | Φ0.5 |
RM6-2 | Vertical | 21.0 | 21.5 | 14.0 | 6 | 3.0 | 6 | 7.0/14.3 | 18.1 | Φ0.7 |
RM6-3 | Vertical | 21.0 | 21.0 | 13.5 | 3 | 3.6 | 3 | 7.0/14.3 | 18.2 | Φ0.5 |
RM6-4 | Vertical | 21.5 | 18.0 | 13.5 | 2 | 3.6 | 2 | 7.0/14.3 | 14.4 | Φ0.6 |
RM8-1 | Vertical | 26.0 | 25.0 | 18.0 | 6 | 3.5/7.0 | 6 | 7.0/14.3 | 18.0/14.3 | Φ0.6 |
RM8-2 | Vertical | 27.0 | 31.0 | 18.5 | 6 | 3.8 | 6 | 7.0/14.3 | 20.3 | Φ0.6 |
RM10-1 | Vertical | 31.0 | 29.0 | 20.0 | 6 | 3.6/7.2 | 6 | 7.0/14.3 | 18.2/21.5 | Φ0.6 |
RM10-2 | Vertical | 30.0 | 38.5 | 20.0 | 6 | 3.8 | 6 | 7.0/14.3 | 28.0 | Φ0.6 |
RM14-1 | Vertical | 44.0 | 43.0 | 30.0 | 6 | 7.0/14.3 | 6 | 7.0/14.3 | 25.2/32.3/25.5 | Φ0.8 |
RM14-2 | Vertical | 44.0 | 51.0 | 30.0 | 6 | 5.1 | 6 | 7.0/14.3 | 35.5 | Φ0.8 |
The aluminum shell dynamic braking resistor is used in various applications to ensure the safe and controlled deceleration of electric motors. Here are some of its primary uses:• Heat Dissipation: The aluminum shell acts as a heat sink, dissipating the heat generated by the resistor during the brak
Calculating the dynamic braking resistor for a Variable Frequency Drive (VFD) involves determining the required resistance value and power rating. Here’s a step-by-step guide:### 1. Determine the System Parameters:- **Motor Power (P)**: in kW or HP.- **DC Bus Voltage (Vdc)**: typically provided by t
Aluminium-housed resistors offer several advantages in high-power industry applications, making them a preferred choice for many engineers and designers. Here are some of the key benefits:• Superior Heat Dissipation: The aluminium housing acts as a heat sink, rapidly dissipating heat during high-po
The electronic products industry market is changing rapidly, requiring basic components to keep up with the pace of product renewal. Especially in the past six months, to cope with the meager and efficient design of downstream general electronic products, some Inductors and transformer using new mat
The principle of the transformer is electromagnetic induction, which is mainly used to change the magnitude of the AC voltage. Transformers are used in the modern electrical industry. Transformers can be divided into many types and are used in many industries. Switching power supply transformers als
The principle of the transformer is electromagnetic induction, which is mainly used to change the magnitude of the AC voltage. Transformers are used in the modern electrical industry. Transformers can be divided into many types and are used in many industries. Switching power supply transformers als